Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 532-536, 2022.
Article in Chinese | WPRIM | ID: wpr-956628

ABSTRACT

Objective:To explore the significance of enthesitis in psoriasis(PsO) and the value of high-frequency Doppler ultrasound (HDUS) in screening potential subclinical psoriatic arthritis(PsA) patients through enthesitis; Designing the semi-quantitative score of enthesitis explore the value of semi-quantitative score in evaluating the degree of joint structure damage and improving the curative effect in patients with subclinical PsA.Methods:Clinical and sonographic data were collected in 125 PsO patients and 50 osteoarthritis (OA) patients who attended hospital from January 2019 to March 2021, and healthy controls (HC) recruited during the same period. The prevalence of enthesitis of distal interphalangeal joint (DIP) of psoriasis patients, osteoarthritis patients and HC was compared. Meanwhile the semi-quantitative scoring system for ultrasound-guided enthesitis was designed, and the correlation between the severity of enthesitis and clinical score was analyzed. The correlation between psoriasis nail and enthesitis of extensor tendon of DIP finger was also analyzed.Results:The significant difference was found in the prevalence of enthesitis of DIP among PsO group, OA group and HC group (all P<0.001); There was a significant difference in the severity of enthesitis of DIP in PsO group before and after treatment ( P<0.001); In PsO group, the correlation between the severity of enthesitis of DIP and Psoriasis Area and Severity Index(PASI)score was moderate ( rs=0.538, P<0.001), and highly correlated with Nail Psoriasis Severity Index (NAPSI) scores( rs=0.877, P<0.001). There was a significant difference in the incidence of enthesitis between the patients with psoriasis nail and the patients without that ( P<0.001). The prevalance of enthesitis of nail disease free fingers was also found significantly different between PsO group and HC group( P<0.001). Conclusions:Enthesitis is a prominent characteristic of PsO.And the semi-quantitative scores designed in this research are in satisfied consistence with the clinical scores, and could be used to evaluate subclinical PsA structural damage.Furthermore, it is possible that the enthesitis of DIP is a relatively independent process from the nail disease.

2.
Chinese Journal of Tissue Engineering Research ; (53): 4857-4862, 2014.
Article in Chinese | WPRIM | ID: wpr-453191

ABSTRACT

BACKGROUND:In previous experiments, a polymer-shel ed microbubble contrast agent was successful y prepared using L-polylactic acid-polyethylene glycol methyl-covered liquid fluorocarbon perfluoropentane, which developed wel in vivo and in vitro under a second harmonic contrast-enhanced ultrasound with a low mechanical index OBJECTIVE:To optimize the conditions for preparing polymer-shel ed microbubble contrast agents with high yield and suitable size. METHODS:The polymer-shel ed microbubble contrast agent containing perfluoropentane was prepared by single emulsion method. Three preparation conditions, including polymer mass/perfluoropentane volume ratio (4/1, 2/1, 1/1, 1/2), hemogenate speed (18 000, 26 000, 35 000 r/min) and time (15, 30, 60, 120 seconds), were optimized, and the microbubble yield and size were set as judge standard. The contrast-enhanced ultrasonography of rabbit kidney was performed using the optimized microbubbles, and the arrival time, time to peak, half time of descending and peak intensity were analyzed by TCA software. RESULTS AND CONCLUSION:The preparation conditions were optimized as a polymer mass/perfluoropentane volume ratio of 2/1, homogenate speed of 26 000 r/min and homogenate time of 60 seconds, which presented a high microbubble yield of (1.8±0.4)×109/mL and mean size of (3.7±1.3)μm with uniform distribution. The arrival time, time to peak, half time of descending and peak intensity were detected as (3.1±0.6) seconds, (2.9±0.5) seconds, (4.0±0.7) seconds and (4.7±1.1)×10-5 AU, respectively. The polymeric microbubbles prepared by optimized conditions were of high yield, with suitable size and good contrast-enhanced effect in vivo.

SELECTION OF CITATIONS
SEARCH DETAIL